title: "Position and optimize IR lights"
canonical: "https://help.vicon.com/space/ShogunMarkerless121/1253507160/Position%20and%20optimize%20IR%20lights"
format: markdown
---
Mount the Vicon IR lights around the volume, pointing each light towards the area to be illuminated.

> ✅ **Number of lights**  
> ✅ We recommend that, whatever the size of your capture area, to ensure even illumination, you use 8 lights.   
> ✅ Depending on the required frame rate, adjust the brightness of the lights. For details, see [Specify the brightness of the IR lights](#specifyBrightness).

1. Position the IR lights around the volume, with a light on either side of the volume corners.
2. Decide whether you need to use 45% or 90% brightness for the IR lights. For details, see [Specify the brightness of the IR lights](#specifyBrightness).

> ⚠️ **Caution**  
> ⚠️ To avoid overexposure when a subject is close to the camera, do not mount the the Vicon IR lights close to the Vicon Vanguard cameras.

For more information about the lights, see the *[Vicon IR Lights Quick Start Guide](https://help.vicon.com/space/markerless/261721779/Vicon+IR+Lights+Quick+Start+Guide)*. 

> Macro (scroll-pagebreak)

> Macro (anchor)



## Specify the brightness of the IR lights

Vicon Shogun Markerless is supplied with two options for the brightness of the IR lights: 45% or 90%.

> ✅ **Tip**  
> ✅ For 30–90 Hz tracking, reduce the brightness of the lights to 45%; for rates 90–120 Hz, use the maximum brightness of 90% and increase the shutter duration.

To choose the required option, you select the appropriate setting for the Lock properties in the **System** panel.

**To specify the brightness of the IR lights:**

1. Ensure that the system is powered and that all the Vicon IR lights are connected to the Vicon Lock via the supplied RCA cable.
2. In Shogun Markerless, go to the **System** panel and in the **Connectivity Devices** section, select the Lock.
3. In the Lock's **Properties**, go to the **GPO Programs** section and for each connected light, click the relevant folder icon.  
By default, the location of the supplied .*gpo* files is displayed.
4. Select the required option and then click **Open**:
  - For 30–90 Hz tracking, select *IR_Lights_DutyCycle45.gpo;* or
  - For 90–120 Hz tracking, select *IR_Lights_DutyCycle90.gpo* (and increase the shutter duration).