title: "Fix bumped cameras"
canonical: "https://help.vicon.com/space/Shogun110/13074964/Fix%20bumped%20cameras"
format: markdown
---
In addition to the following information, see also the Vicon video: [5 - Shogun Live - System Health and Camera Fixing](https://youtu.be/h8cljyODIVI).

> Macro (scroll-ignore)
> 
> > Macro (widget)

Vicon cameras with accelerometers (Vicon Vantage, Vero, Vue, and Valkyrie), provide a bump detection feature. On these cameras, the status indicators flash blue when the camera is bumped and (on Valkyrie and Vantage cameras only) the display changes to indicate a bumped camera. In the Vicon Shogun Live **System** panel, icons are displayed to the right of the camera names to indicate a bump.

![image](media://c1b11808-8a5f-40e9-956d-e03e50a00591)

To prevent you from having to recalibrate the whole system after a camera has received a minor bump, when a calibrated subject (or prop, or wand) moves through the volume, cameras automatically detect whether further action is necessary:

- If a calibrated subject moves through the volume and the cameras have returned to their original position, the cameras’ bump status indicators stop flashing blue and in the **System** panel, the bumped icons disappear.
- If you need to take further action, the status lights continue to flash blue and the bumped icons remain on the **System** panel.

As an additional check, in the **System** panel click the camera with the bumped icon to select it and in a **Cameras** view, zoom in on the markers. When a camera is bumped, red warning symbols are displayed, indicating the difference between where the system expects the markers to be, and where they actually are.

![image](media://7a6401c2-cafd-416e-ba08-d747e6175836)

Shogun Live enables you to quickly correct a camera whose position has changed due to having been bumped or moved, using any labeled object in the volume – subject, prop, or wand, and the **Recover Camera Pose** feature.

> ⚠️ **Important**   
> ⚠️ You can use **Recover Camera Pose** to recover cameras that have been either bumped or moved. This process relies on having enough cameras within a calibrated system to act as a calibration anchor. For this reason, it is recommended that it is run on only a small proportion of the cameras in a system. A single camera or a small number of affected cameras can be recovered with good results. If a larger number of cameras is affected, perform a full camera calibration instead (see [Calibrate cameras](https://vicon-help.atlassian.net/wiki/spaces/Shogun110/pages/13074465)).

> Macro (scroll-pagebreak)

## Correct a bumped or moved optical camera

The following procedure corrects a bumped optical camera (Vantage or Vero): for bumped video cameras, see [Correct a bumped Vicon Vue video or SDI video camera](#VideoRecal).

1. On the **System** tab, select the camera that was bumped or moved.
2. On the **Camera Calibration** tab, in the **Calibration Healing** section, click **Recover Camera Pose**.
3. In the volume, have the subject move (or move the labeled object) in front of the affected camera.
  In the **3D View** and **Cameras** view, you can see orange trails as the system determines the offset between the camera and the rest of the calibration.
4. When enough of the view has been covered (indicated by orange trails that thickly cover the affected camera view, as shown above), select **Stop Recover Camera Pose**.
5. In the **Cameras** view, zoom in and check that the markers are now aligned, with no red warning symbols.
  The camera is now correctly aligned with the rest of the system. Note that masking of the affected camera is not preserved, so for optimum results, you may need to mask this camera again.

> Macro (anchor)



## Correct a bumped or moved Vicon Vue video or SDI video camera

Note that to correct a Vue camera, you need to use active markers, so ensure you have a Vicon Active Wand to use during the procedure.

1. On the **System** tab, select the video camera(s) that are bumped, or that have been moved.
2. With the video camera(s) still selected, in the **Camera Calibration** panel, go to the **Wand Wave** section, display the advanced options > Macro (inline-media-image)

 and then click **Selected**.
3. With **Auto Stop** selected, wave the wand for just the selected cameras and wait for the calibration to finish.
  In the **3D View** and the **Cameras** view, the camera view is covered with orange trails.
4. In the **Cameras** view, zoom in and check that the markers are now aligned.