title: "Communications pane"
canonical: "https://help.vicon.com/space/Nexus215/11372215/Communications%20pane"
format: markdown
---
The **Communications** pane enables you to view and manage the state of your Vicon system, and streamline your motion capture workflow.

The tabs at the bottom of the **Communications** pane enable you to switch between the available monitoring tools.

> ✅ **Tip**   
> ✅ To avoid the pane taking up too much onscreen space, you can choose to hide the **Communications** pane when you load a trial. To do this, on the **Window** menu, select the **Close Communications Pane on Trial Load** option. Alternatively, to temporarily hide/reveal the **Communications** pane, so that the tabs are minimized to the bottom of the screen without completely closing, double-click any of its tabs.  
> ✅ You can also hide individual tabs by clearing options in the **Plug-ins** panel (**Window** menu > **Plug-ins**) and then restarting Nexus.

> Macro (scroll-only)
> 
> For information, see:
> 
> 
> > Macro (toc)

> Macro (scroll-pagebreak)

## Data Management tab

The **Data Management tab** contains the following controls:

- **Database location** You can view the full path of the active node in the trial database at the top of the **Data Management** tab. To access the files in Windows Explorer, click the hyperlink.
- **Navigation buttons** > Macro (inline-media-image)

 You open the **Manage Databases** dialog box, go forward a node, go back a node and move up a level using the navigation buttons at the top left of the **Data Management** tab.
- **Search button** > Macro (inline-media-image)

 Displays or hides the **Search** window. For more information, see [Advanced data searching](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11379384).
- **Show Trial Loading Options button** > Macro (inline-media-image)

 Displays or hides the **Raw Data Loading Options** area, in which you can specify your requirements for loading large trials.  
For more information, see [Load large trials](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11379191).
- **Show File Transfer/Batch Processing Interface** button > Macro (inline-media-image)

 Displays or hides the **Remote File Transfer/Batch Processing** pane on the right side of the **Data Management** tab.  
For more information, see [Work with digital video files](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11374204) in the *Vicon Nexus User Guide* and [Batch process trials](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11378827).
- **Data Management toolbar** You create and manage nodes in the database hierarchy using the buttons in the toolbar at the top right of the **Data Management** tab. From left to right, the buttons are:
  - New Patient Classification button > Macro (inline-media-image)
  - New Patient button > Macro (inline-media-image)
  - New Session > Macro (inline-media-image)
  - New Polygon Report > Macro (inline-media-image)
- **Database hierarchy nodes** You view a visual representation of the structure and contents of a trial database, and select individual data types for loading in Nexus, in the nodes on the **Data Management** tab.
- **Data type icons** > Macro (inline-media-image)

 > Macro (inline-media-image)

 > Macro (inline-media-image)

 > Macro (inline-media-image)

 You can view and select individual motion capture files using the icons that represent the data saved for the trial.
- **Data fields** You can view or enter descriptive text or numerical data associated with a specific node in the trial database in the fields in the columns to the right of a node name.

For information on using Data Management in Vicon Nexus, see [Data management with Nexus](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11375311).

## Quality tab

The data **Quality** pane, a tab in the **Communications** window, provides an overview of data quality for a subject across a whole trial and enables you to examine the health of individual trajectories. It also provides a way to navigate to the highlighted issues.

The display options in the **Options** column enable you to configure the display options for this tab. Alternatively, you can open the **Options** dialog box (F7), click **Data Quality Panel Options** on the left, and change the properties as required.

The **Trajectory Sort Value** list contains the following options:

- **Percentage Labeled** Orders blobs with the highest labeling percentage first (from top left).
- **Max Gap** Orders blobs with the trajectories containing the longest gaps first (see the **Max Gap Length** column of the **Gap Filling** section in the** Label/Edit Tools**).
- **Model Order** Displays blobs in the same order as the markers are listed under the **Markers** node in the **Subjects Resources** tree.
- **Number Of Gaps **Orders blobs with the trajectories with the highest number of gaps first (see the **#Gaps** column of the **Gap Filling** section in the** Label/Edit Tools**).
- **Trajectory Length** Orders blobs with the longest trajectories first.

You can also select other options in the **Options** column to tailor the display to your requirements.

To save any changes to these settings, click the **Save current configuration** button in the **Options** dialog box.

For information on using the **Quality** tab, see [ Assess trial health with the data Quality pane ](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11375538/Review+data+quality#DQP) in the *Vicon Nexus User Guide*.

## History tab

The **History** tab in the **Communications** pane enables you to review all processing that has been performed on a loaded trial file.

This ensures that, even if you have not worked with the data before, you can continue to work on the trial without missing or duplicating processing steps performed by another Nexus user.

To display information about a particular event, click on the event on the **History** tab. Details about the settings used to run the event are displayed in the **Property** and **Value** columns on the right.

In the **Notes** field, you can add notes that will be useful to you or anyone else working with the same trial. Your notes are saved with the trial.

> ℹ️ **Note**   
> ℹ️ A processing history is available only for files processed in Nexus 2.3 and above.

## Theia tab

The **Theia** tab in the **Communications** pane enables you to access the **Theia Batch Interface**. From here you can select the required video files and process them. The files are processed through Theia3D, resulting in the output of C3D file(s) that contain rotation data for each subject.

> ✅ ** Tip**   
> ✅ Unlike the **Theia** pipeline operation, which loads each trial into Nexus, when you use the Theia Batch Interface, you can process your optical data at the same time in Nexus while Theia runs and processes the video data in the background.

For more information, see [Run Theia processing on video files](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11375075) in the *Vicon Nexus User Guide*.

## Python tab

The **Python** tab in the **Communications **pane enables you to set the path to your Python installation, and run Python scripts. For more information, see [Modeling with Python](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11370595).

## Matlab tab

The **Matlab** tab in the **Communications **pane enables you to run MATLAB scripts and launch MATLAB. For more information, see [Modeling with MATLAB](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11377520).

## Monitors tab

The **Monitors** tab enables you to configure monitors that you create in the Graph view pane to detect motion capture events.

For information on creating and using monitors and detailed descriptions of the options, see [Using monitors](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11375419).

The **Monitors** tab contains the following areas:

### Monitors configuration management area

You manage monitor configurations in the **Monitors** tab using the configuration management section at the top of the pane.

> Macro (scroll-pagebreak)

### Monitors area

The **Monitors** area enables you to define the monitor behavior. It contains the following components:

> Macro (scroll-tablelayout)

| **Component** | **Description** |
| --- | --- |
| Monitors list | Lists the currently defined monitors. Select the check box next to a monitor name to enable the monitor, or clear the check box to deactivate the monitor. Select a monitor in the list to view or configure its properties. |
| AND button | When multiple monitors are selected from the list, this button adds a Boolean AND monitor that triggers an action when all of the monitor trigger conditions are present. |
| OR button | When multiple monitors are selected from the list, this button adds a Boolean OR monitor that triggers an action when at least one of the monitor conditions is present. |
| Remove button | Removes the selected monitor from the list. |
| Clear button | Removes all monitors from the list. |

### Actions area

The **Actions** section of the **Monitors** tab enables you to view or modify monitor action settings. It contains the following components:

> Macro (scroll-tablelayout)

| **Component** | **Description** |
| --- | --- |
| Actions list | Actions that you add will execute when the monitor threshold and trigger conditions are met. |
| Add button | Click to add the selected action to the Actions list. Select from: Capture, External trigger, Timebar Event, Progress Bar, Range Overlay, Sound Tone, Toggle Monitor and Play Sound File. |
| Remove button | Click to remove the selected action from the Actions list. |
| Clear button | Clears all actions from the Actions list. |

> Macro (scroll-pagebreak)

## > Macro (anchor)

 IMeasureU tab

The **IMeasureU** tab enables you to work with data recorded from Vicon IMUs (Inertial Measurement Units).

After you have finished capturing data and have plugged the IMUs into the PC, you use the IMeasureU tab to work with and transfer the data from the IMUs to the Nexus Session folder.

For information on working with IMUs and Nexus, see  [Work with Vicon IMUs](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11372271)  in the *Vicon Nexus User Guide*  .

The IMeasure U tab contains the following areas:

- [Transfer pane](#Transferpane)
- [Alignment pane](#Alignmentpane)

### Transfer pane

> Macro (anchor)




The **Transfer** pane of the **IMeasureU** tab lets you transfer data captured with Vicon IMUs to the current Session folder in Nexus. It contains these components:

> Macro (scroll-tablelayout)

| **Component** | **Description** |
| --- | --- |
| Transfer list:  
Trial column and   
Progress column | The Trial column lists the trials currently stored on connected IMUs.  
The Progress column displays the current transfer status of each captured trial. |
| Select All button | Selects all the trials for each sensor that is listed in the Transfer pane. |
| Select None button | De-selects all selected trials that are listed in the Transfer pane. |
| Select Transferred button | Selects all trials for each sensor that is listed with **Transferred** progress status |
| Select Untransferred button | Selects all trials for each sensor that is listed with **Not Transferred** progress status |
| Select Connected button | Selects only IMUs that are connected to Nexus |
| Select Disconnected button | Selects only IMUs that are not connected to Nexus |
| Remove Selected Trials button | Removes selected trials from the list. Existing data for these trials remains on the device but is not accessible via Nexus. |
| Clear Selected Devices button | Removes selected devices from the list. Existing data remains on the device but is not accessible via Nexus. |
| Erase Selected Devices button | Erases all data from the selected devices. Successfully cleared trials are removed from the list. |
| Transfer Files button | Transfers selected trials from connected IMUs to the current Session folder in Nexus. |
| Cancel Transfer button | Cancels the current transfer operation. |

### Alignment pane

> Macro (anchor)




For information on using the controls in the Alignment pane, see [Align IMU data with the Vicon world](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11372271/Work+with+Vicon+IMUs#AlignIMUwithVicon) in the *Vicon Nexus User Guide*.

> Macro (scroll-pagebreak)

## Theia tab

The **Theia** tab enables you to process Nexus video data from within Theia3D, without having to launch Theia3D and manually process the data.

The **Theia Batch Interface** on the left enables you to select the required video files to process and to run Theia processing on all the files in the specified session folder. The files are processed through Theia3D, resulting in the output of C3D file(s) that contain rotation data for each subject. You can then run Nexus pipeline operations to merge the rotations into your Nexus subject and to calculate the joint angles, all without leaving Nexus.

> Macro (scroll-only)
> 
> The Theia tab contains the following areas:
> 
> > Macro (toc)

For more information, see [Run Theia processing on video files](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11375075) in the *Vicon Nexus User Guide*.

### Theia Batch Interface

> Macro (scroll-tablelayout)

| **Component** | **Description** |
| --- | --- |
| Folder field | Enter or browse to the full path of the video trials that you want to process in Theia.  
Note that when you exit and relaunch Nexus, the path is remembered. |
| Theia executable field | Enter or browse to the full path for the *Theia3D.exe *file, for example, *C:\Program Files\Theia\Theia3D*.   
Note that when you exit and relaunch Nexus, the path is remembered.   
If Theia closes, Nexus tries to relaunch Theia for a single retry for a trial. If the trial won't open, it moves on to the next trial. If you want to stop Theia launching, click **Cancel processing**. |
| Theia preferences field | If you want to use the preferences that you use in Theia, enter the full path to the required Theia prefererences file. This must be exported from Theia and saved as a PXT file on the local machine. |
| Create folder hierarchy check box | If you want a folder hierarchy to be created, using the trial video files, ensure that this check box is selected. Unless you have a specific reason to save your files elsewhere, leave this option selected. |
| Process trials in folder button | Click to process the files specified in the **Folder** field. |

### Theia processing results area

In this area on the right of the Theia tab, the results of processing the specified files are displayed. Details include the time and the current status of the processed files. When processing is finished, the right side of the Theia tab displays the text '**Batch Processing: Finished.**'

## MATLAB tab

Enables you to execute a MATLAB script from within Vicon Nexus. For more information, see [Modeling with MATLAB](https://vicon-help.atlassian.net/wiki/spaces/Nexus215/pages/11377520).

> Macro (scroll-pagebreak)

## > Macro (anchor)

Status tab

Enables you to monitor the state of your Vicon system during any stage of the Nexus motion capture workflow. This is useful for identifying problems and determining the Nexus system component that needs to be examined.

The **Status** tab contains the following sections:

- **Status Summary**   
View a visual summary of the status of system components in the **Status Summary** section of the Status communications pane:
  - **Vicon Cameras**   
View the status of Vicon cameras.
  - **Video Cameras**   
View the status of digital video cameras.
  - **Connectivity**   
View the status of Vicon connectivity units.
  - **Capture **   
View the status of capture sessions in Nexus.
  :check_mark: The background in each summary corresponds to the icon displayed for the devices in the **System Resources** pane. The color of a summary border reflects the status for the set of components:
  - Green: All components OK
  - Yellow: One or more components are on standby
  - Red: One or more components are down
  
- **Status Details**   
View details of the status of a system component in the Status Details section of the Status tab. The contents of this section depend on the component you click on in the Status Summary section.

> Macro (scroll-pagebreak)

## Log tab

Enables you to monitor Nexus system activity and troubleshoot any errors. For example, if a pipeline operation fails (indicated by a red X next to the operation in the **Pipeline Tools** pane), you can find information as to why the failure occurred on the **Log** tab.

The icon on the **Log** tab > Macro (inline-media-image)

 automatically appears to scroll to indicate that a warning is displayed (for example, a new log entry indicating that an operation has failed).

You are alerted to important errors by popup notifications that are briefly displayed at the bottom right of the Nexus window.

![image](media://f10b20cc-aa29-43f5-aad9-a6fd031ce97c)

If you are using the default sounds supplied with Nexus and have audio enabled, a relevant sound clip is also played.

To view further details about the error in the Log, click the notification.

The notification disappears after four seconds.