title: "Get to know Vicon Nexus"
canonical: "https://help.vicon.com/space/Nexus212/11249405/Get%20to%20know%20Vicon%20Nexus"
format: markdown
---
The  Nexus user interface  enables you to access the tools you need quickly and easily. Within the primary panes ( Resources ,  View ,  Tools , and  Communications ), you use the tabs and buttons to open secondary panes containing tools and options for specific parts of the motion capture workflow. Click to enlarge this image   Resources pane:  Manage the different components of your Vicon system, and the subjects whose motion is to be captured, on the  System  tab and the  Subjects  tab. See  Manage system and subjects in the Resources pane .   View pane:  Set up the way you want to visualize the capture data from one or more cameras (or supported third-party devices) either live in real time or offline, from a saved file. See  Display data in the View pane .    Tools pane : Work through the main stages of the motion capture workflow, using the tabs in the Tools pane from left to right: System Preparation, Subject Preparation, Capture, Label/Edit and Pipeline (this last tab enables you to group and run operations that you use throughout the workflow). See  Manage the motion capture workflow in the Tools pane .     Communications pane:  Store and manage all data associated with your motion capture trials ( Data Management  tab: see  Manage mocap data on the Data Management tab ), assess trial health ( Quality  tab: see  Review data quality ), view stored processing history ( History  tab: see  Review processing history ), set up and control monitors for your trials ( Monitor  tab), use Vicon IMUs with Nexus ( IMeasureU  tab: see  Work with IMUs ), interact with MATLAB ( Matlab  tab: see  Modeling with MATLAB ), view system status information ( Status  tab), and view a log of Nexus system activity since start up ( Log  tab).   Menu bar:  Access menu options. See  Access menu options from the Nexus menu bar .    Toolbar:  Access frequently used commands and create and select view types. See  Access common commands from the Nexus toolbar . Basic keyboard shortcuts and mouse actions You can use the mouse to manipulate items and manage the way data is visualized in Nexus, and you can combine standard mouse actions with keyboard keys. The following mouse and keyboard combinations are used most frequently in Nexus. 
                 Navigate in the 3D Perspective view: 
             Zoom: Right-click + drag forward or backward Orbit: Click + drag Translate/Move: Click wheel button (or left-and-right-click) + drag Tip   To open files in Nexus, in addition to loading files as described in  Play back data with the time bar , you can drag and drop Nexus files onto a  3D Perspective  view (or any other view). File types that you can load in this way include: C3D, ENF, VSK/VST, X1D, X2D, and XCP. Select objects in the view pane : Select a single item: Click Select multiple consecutive items: SHIFT + click Select multiple non-consecutive items: CTRL + click Select items within a bounding outline: ALT + click and drag 
                 Display/hide a section within a pane: 
             Click the Display Section arrow on the right Click the Hide Section arrow on the right For lists summarizing more Nexus shortcuts and mouse actions, see  Hot keys and shortcuts . For more information on getting to know the Nexus user interface, see: 
                 
             Manage mocap data on the Data Management tab The  Data Management  tab of the  Communications  window enables you to create a hierarchical structure in which to store and manage all the data associated with your motion capture trials. For information on how to do this, see  Prepare a data storage location . Tip   To toggle the display of the  Data Management  tab, press F2. It also enables you to: Assess trial health with the tools on the  Quality  tab. For more information, see  Review data quality . View processing history on the  History  tab. For more information, see  Review processing history . Set up and control monitors for your trials with the  Monitor  tab. Interact with MATLAB. View system status information on the  Status  tab. View a log of Nexus system activity since start up on the  Log  tab. 
                 
             Manage system and subjects in the Resources pane To manage Nexus system connection and real-time data-streaming, click the system connection buttons at the top of the  Resources  pane: Go Live : Connect the system and start real-time data streaming. The button's label changes to  Go Offline . Go Offline : Disconnect the system and stop real-time data streaming. The button's label changes to  Go Live . Pause : Pause real-time data streaming. When you click the Pause button while the system is in Live mode, the button turns blue and a pause symbol   is displayed in the view pane. When the system is in Offline mode, the button is unavailable. At the top of the  Resources  pane, click the tab for the resources you want to manage: System : View and configure Vicon system components Subjects : Load and manage files for mocap subjects In the  System Resources  tree or  Subjects Resources  tree, select the item(s) you want to configure. Depending on whether you are in Live mode, you can then: Right-click a node to display a context (shortcut) menu of commands that can be applied to that item, if one exists. In the  Properties  pane below the  Resources  tree, view the settings for the item(s) selected in the tree. To view all of the available properties, click  Show Advanced . For more information, see  Set properties in Vicon Nexus . 
                 
             Set properties in Vicon Nexus You can configure certain aspects of the Nexus system, such as system components and motion capture subjects, by configuring settings in the corresponding  Properties  section of the user interface. Required properties for which you must specify a value are indicated in the Nexus user interface with a shaded background. Some properties settings automatically persist, so Nexus remembers them in subsequent sessions. You must explicitly save other settings using the relevant configuration management controls for that area of the Nexus window. 
                 To set properties in Nexus: 
             In the Nexus window, open the pane or dialog box containing the properties whose settings you wish to configure. For example: System components -  System Resources  pane Motion-capture subjects -  Subjects Resources  pane Camera calibration process -  System Preparation Tools  pane Subject calibration process -  Subject Preparation Tools  pane Data processing operations -  Pipeline   Tools  pane Monitor and event actions -  Monitors  tab in the  Communications  pane Data visualization -  Options  dialog box To view all of the available properties, click the  Show Advanced  link. To show only the basic properties, click the  Hide Advanced  link. View or change the setting for the desired properties using its entry field or control. When you are working in the following areas of the Nexus window, you can save any changes you have made to the settings, using the configuration management controls (indicated in the following images). Your settings are saved to a configuration file, so that you can re-use them later. System Resources  pane Pipeline Tools  pane Monitors  tab in the  Communications  pane Options  dialog box (press F7 to display) Nexus toolbar (working with the layout of the view panes)   For more information on configuration files, see  Manage configurations in Vicon Nexus . 
                 
             Display data in the View pane At the left of the View pane toolbar, click the drop-down list and select one of the available views: 3D Perspective : Display 3D reconstructions of Vicon camera data. 3D Orthogonal : Orthogonal views of 3D data: -Z, +Z, +X, -X, +Y, or -Y  RGB = XYZ Camera : Display 2D optical data from Vicon cameras or video streams from connected video cameras. Graph : Display variables (model outputs), or system components such as force plate or EMG activity. Subject Viewer : Display the base (default) pose for the labeling skeleton template (VST) of the currently selected subject. This is useful when you are calibrating and manually labeling a labeling skeleton, which are explained in  Prepare a subject .  At the right of the View pane toolbar, click the buttons to specify the number and arrangement of views displayed: Horizontal Vertical Close Depending on the view selected, additional lists and buttons are available to manage the display options. Tip   To display multiple  Camera  views, in the  System Resources  tree, SHIFT+click to select multiple cameras and in the View workspace, select  Camera  view. 
                 
             Manage the motion capture workflow in the Tools pane At the top of the  Tools  pane, click the buttons for tools relating to the stage in the workflow that you want to display. The buttons are displayed in the order of a typical Nexus workflow (from left to right) and are enabled appropriately, depending on whether you are in Live or Offline mode (the following image is in Live mode).   System Preparation : Prepare your Vicon system for motion capture.   Subject Preparation : Prepare subjects whose motion is to be captured.   Capture : Collect motion data.   Label/Edit : Label and fill any gaps in trial data.   Pipeline : Create and manage sequences of operations to process trials. To find out more about the motion capture workflow, see  Vicon Nexus motion capture workflow . 
                 
             Play back data with the time bar To explore the time bar: Ensure a  3D Perspective  view is displayed (see  Display data in the View pane ). On the  Data Management  tab at the bottom of the Nexus window, navigate to an existing database. You can do this by expanding the displayed hierarchy and using the  Go forward to the next node ,  Go back to the last node , and  Move up one folder level  buttons  . In the  Name  column, double-click the trial that you want to load.  Nexus opens the trial. On the time bar, click the  Play  button or drag the current time indicator (blue vertical line) to play back offline capture data. To crop a trial (restrict playback to a range of frames), you can drag the Start and End Range indicators (the blue triangles at the top of the timeline) along the time bar. To hide or display the  Data Management  window, double-click the  Data Management  tab at the bottom of the Nexus window. Tip   In addition to using the time bar to view and navigate trials, you can also use it to: • View data quality as a heat map. For more information, see  Review trial data using the time bar . • Create and manage events (for example, a foot striking a force plate, or a joint attaining a specified angle, etc). For more information, see  Add events to trials . 
                 
             Access menu options from the Nexus menu bar The Nexus menu bar enables you to access common commands. 
                 
             Access common commands from the Nexus toolbar Access frequently used commands from the Nexus motion capture workflow from the Nexus toolbar. The Nexus toolbar contains buttons that enable you to save the current trial, close the current trial, and undo and redo actions. In addition it contains the following controls:  Reconstruct  Runs the  Reconstruct  pipeline defined in the  Pipeline Tools  pane. (Reconstruction is the process by which Nexus calculates the position of markers in three-dimensional space and links these points frame-by-frame into a trajectory.) For examples of using this pipeline, see  Calibrate a labeling skeleton .   Reconstruct and Label  Runs the  Reconstruct and Label  pipeline defined in the  Pipeline Tools  pane. (The Label process is where labels defined in the labeling skeleton template for the subject are applied, either manually or automatically, to a point in the trajectory of a marker.) Normally used when processing trials. For an example of using this pipeline, see  Reconstruct and label movement trials .   KinFit   Runs the  Kinematic Fit  pipeline defined in the  Pipeline Tools  pane. This pipeline is often used before running a  Fill Gaps - Kinematic  operation for filling gaps in trajectories, and for visualizing or graphing segment- or joint-based data in realtime.   AutoInitialize   Runs the  Auto Initialize Labeling  pipeline defined in the  Pipeline Tools  pane. Often used as part of calibrating a labeling skeleton For an example of using this pipeline, see  Calibrate a labeling skeleton .   Auto Gap Fill   Runs the  Auto Intelligent Gap Fill  pipeline defined in the  Pipeline Tools  pane. This enables you to quickly fill gaps in your trial, without having to choose which fill method is best for each gap. For good results, you must configure the relevant pipeline operations for your particular trials. For information on using this command, see  Automatically fill gaps in trial data .   Add To Quick Report  Adds the current trial to a Quick Report. For more information, see  Quick Reports  in the  Vicon Nexus Reference Guide . Any user-customized buttons  If required, you can create your own additional buttons and configure them to run a specified pipeline or load a previously created view configuration. You can create or change toolbar buttons in the  Customize Toolbar  dialog box.   View Type  list Lists any saved view types. The adjacent configuration buttons enable you to create   and save   custom view types. Clicking a button on the toolbar executes the defined action for the button. A button is dimmed if it is not available, for example, if it cannot be run at that stage of the workflow or if a customized button has been deleted or renamed. Tip   To display a tooltip that explains why a button is unavailable, hover the mouse pointer over the button. 
                 
             Manage configurations in Vicon Nexus You can determine how Nexus looks and behaves by creating and editing configurations in the configuration management controls in the Nexus window. To view and select any default configurations that were installed with Nexus, click the dropdown list in the relevant configuration management controls, for example, for View Types: You can create different configurations to suit different types of motion capture applications and then select the appropriate configuration when required. You can also save configurations for use by multiple users (Shared) or for a specific user (Private), to suit your organization: Shared  These configurations can be viewed by all users; they can be changed only by the user who was logged on when the file was first created and saved. Shared configuration files are stored in the appropriate folder, by default under:  C:\Users\Public\Documents\Vicon\Nexus2.x\Configurations Private  These configurations can be viewed and changed only by the user who was logged on when the file was first created and saved. Private files are stored in the appropriate folder under the logged-in user's Application Data files folder, by default under:  C:\Users\<UserName>\AppData\Roaming\Vicon\Nexus2.x\Configurations\ System  These configurations are the default configurations that are installed with Nexus and are stored in the Nexus configurations folder, by default: C:\Program Files (x86)\Vicon\Nexus2.#\Configurations For more information, see  Recognize Shared, Private, and System files . Important   The default Nexus toolbar is stored in the  Standard.toolbar  configuration file in the  Shared  Nexus configuration folder  Toolbars . If you add, delete, or reposition buttons on the Nexus toolbar using the  Customize Toolbar  dialog box, these customizations are stored in your  Private  configuration folder. 
                 
             
                 To manage configurations in Nexus:  
             In the Nexus window, open the pane or dialog box containing the type of Nexus configuration file you want to manage (see  Configurations table ). Depending on whether you want to create a new configuration or change the current configuration either: Leave the currently loaded configuration file. (If no configuration file has been created yet,  Untitled * is displayed and no other options are available.) or Select another configuration file from the dropdown list. If you have made changes to the current configuration file, Nexus prompts you to save these before changing the configuration file. In other areas of the Nexus pane or dialog box, make any desired changes to settings, such as those in a  Properties  section. Click the configuration menu button   and select the required command from the displayed list: New : Create a new configuration in which to save the current settings. The name  Untitled * is displayed in the  Choose configuration  list. Save    As : In the  Save As  dialog box, enter a name to overwrite the default new configuration file name  Untitled * or to create a new system configuration file in which to save a copy of the current configuration file and click OK. Additional options include: Rename : In the  Rename  dialog box, enter a new name for the currently loaded configuration file and click OK. Delete : At the  Delete  prompt, click Yes to delete the current file displayed in the configuration dropdown list. Mark Read-Only : Select to protect the current configuration file from further changes. Set Defaults : Returns values to their default settings. Import : Enables you to select and import a configuration file. This is useful when you want to copy a configuration file from another machine. Reload : Reload or delete an automatically saved configuration file. You can select from the list of timestamped files or, if required, delete all the saved configurations. Refresh List : Re-display the contents of the configuration dropdown list. This is useful if you copy a file into one of the  Configurations  sub-folders, enabling you to update the options displayed in the relevant list, without having to re-start Nexus. In the  Configuration type  dialog box, select the user permissions for the configuration:  Shared  or  Private . The new file name is displayed in the configuration dropdown list. Click the Save button to store the settings in the configuration displayed in the configuration dropdown list. For more information, see  Set properties in Vicon Nexus . 
                 
             Configuration types and settings locations Nexus UI area Configuration type Configurations folder\file Capture Tools  pane Motion capture settings TrialTypes\*.TrialTypes Biomechanics Workflow area of  Communications  pane Biomechanics workflow CaptureWorkflows\*.CaptureWorkflow Sounds  dialog box Sounds settings AudioSchemes\*.AudioScheme Monitors  tab in  Communications  pane Event monitors and actions Monitors\*.Monitors Options  dialog box Data view options Options\*.Options Pipeline Tools  pane Automated processing operations Pipelines\*.Pipeline System Resources  pane System settings Systems\*.System Toolbar Toolbar buttons Toolbars\*.Toolbar (see Important note above) View pane View options and layouts ViewTypes\*.ViewType 
                 
             Recognize Shared, Private, and System files When pipelines, view types, monitors, labeling skeleton templates, and configurations are displayed in Nexus (ie, listed in menus, etc), you can immediately recognize whether they are Private, Shared, or System files: Icon File type Description Shared Can be viewed by multiple users; can be changed only by the user who was logged on when the file was first created and saved. Shared files are stored in subfolders in: C:\Users\Public\Documents\Vicon\Nexus2.x Private Can be viewed and changed only by the user who was logged on when the file was first created and saved. Private files are stored in subfolders in: C:\Users\ <usrname> \AppData\Roaming\Vicon\Nexus2.x System Cannot be changed (Read-Only) and are upgraded when the next version of Nexus is installed. Stored in subfolders in the Nexus installation folder, whose default location is: C:\Program Files (x86)\Vicon)\Nexus2.# or C:\Program Files\Vicon\Nexus2.# 
                 
             Customize the Vicon Nexus user interface In addition to the usual resize and close window options, you can slide the  Resources  and  Tools  panes to either side of the Vicon Nexus window and or minimize the  Communications  pane, to give you a larger workspace area. Requirement Action Button To hide the  Resources  and/or  Tools  panes At the top of the  Resources  or  Tools  pane, click the  UnPin  button. To hide the  Communications  pane Double-click a tab within the  Communications  pane; or To hide the pane whenever you load a trial, on the  Window  menu, select the Close Communications Pane on Trial Load  option. 
                         To reveal the  Resources  and/or  Tools  panes Click the text at the top of the tab at the side of the Nexus window.  or  To reveal the  Communications  pane Double-click a tab within the  Communications  pane; or To make the pane visible whenever you load a trial, on the  Window  menu, clear the Close Communications Pane on Trial Load  option. 
                         To return a pane to being locked into place At the top of the pane, click the  Pin  button. To undock (float) and dock a pane At the top of the (pinned) pane, click the  Undock  or  Dock  button.  or  Customize a View pane The View pane cannot be undocked, repositioned, or resized in the Nexus window. However, you can open a separate floating view pane by selecting the  New floating workspace  command from the  Window  menu. This floating workspace can be repositioned and resized. The width of the View pane is affected by resizing panes to the left and/or right of it. The height of the View pane is affected by resizing the panes below it.